What are the limitations for Lock source and Output types?

How many Output types are active at the same time?
Answer
In general, the scaler's output is limited to only one of the following at a time:

a) RGBHV
b) RGBS
c) RGsB
d) YUV
e) CV, YC and SDI simultaneously

Thus it is not possible to output RGBHV and CV at the same time.

Also, since a Lock source (when Lock method is no Off) controls the scaler's output, the Output types listed above are determined by the Lock source type (RGBHV, CV, etc.) since they must match.

Thus if locking to a YUV input, only a YUV output is available. Locking to a CV source causes CV, YC and SDI to be output at the same time - as per the above table.